In short

  • Contact faded within about 15 minutes as the skin dried.
  • The eye check now checks contact first and saves its recording.
  • Research: the gold standard for eye signals is EOG, with electrodes beside the eyes.
On this page

The first eye checks with a real headband

Two runs of the eye check, both 0 of 3 blinks and 0 of 4 eye movements. Before blaming the eyes, we looked at the data again.

Contact changes from minute to minute

Sensor15:11, forehead just dampened15:27, sixteen minutes later
AF7, left foreheadtouching skinidentical to AF8, 32% mains hum
AF8, right foreheadtouching skinidentical to AF7, 32% mains hum
TP9, left earno contactstill floating
TP10, right earno contacttouching skin

As the water dried, the forehead sensors went back to behaving like one antenna. You cannot see eyes through sensors that aren’t touching, so the eye check never stood a chance.

This is the core problem for a whole night: with this headband and this skin, dry contact does not hold. Moisture helps for a few minutes, then fades.

What we changed

  • The eye check now shows the forehead contact before it starts and warns when AF7 or AF8 is below 80%, instead of running a test that can’t succeed.
  • It saves its recording (AF7, AF8 and the exact time of every prompt) to Documents/OpenLucid/eyecheck-*.csv, so a failed check can be analyzed.
  • Two fixes in how it judges: the filter no longer starts with a jolt (raw EEG begins hundreds of microvolts from zero), and a blink is measured against the moment just before it, so a drifting sensor can’t hide it.

What the research standard says

We asked: how does science record eye movements during sleep, and what can a home project realistically use? The full answer, with sources and prices, is on the research page. The short version:

  • Sleep labs record eye movements with EOG: two electrodes beside the outer corners of the eyes. Lucid-dream research has verified the left-right signal this way since 1981. A horizontal EOG is the gold standard.
  • A forehead headband like the Muse sees eye movements only approximately. One independent study found the Muse S scores REM sleep well against a sleep lab, but nobody has published a test of left-right signal detection on a consumer headband. That is open territory, and worth testing ourselves.
  • A cheap way to get real EOG at home: stick-on electrodes beside the eyes with an open amplifier (OpenBCI, or an educational kit like BITalino). Battery-powered only, never connected to a charging laptop.

Next

  • Try the eye check again right after dampening the forehead, while both forehead sensors are green.
  • Decide whether to add a real EOG channel next to the Muse, to test how well the forehead sees what the EOG sees.